Latest revision 15 July 1997 TJD 10643 = July 14, 1997 TTE, TTS, MER data, Trigger Number 6307 The data in the TTE, TTS, and MER files for trigger number 6307 at TJD/SoD = 10643/38817 seem to be corrupted. The reason is not understood but may be a hardware problem. This is the third known such occurrence, all of which have been since the first set of burns (apogee-raising) for the last reboost. The data in the TTS and MER files seem to be for the preceding event. The TTE data seem to change from the trigger detectors to another detector. The trigger detectors (DSELB) were 4 and 5. The first board of TTE (pre-load time) has all detectors as it should. The first two packets and part of the third packet of the second TTE board (post-load time) have detectors 4 and 5 as they should. However, part of the way through the third packet and for the remainder of the TTE file, only detector 1 (not even one of the trigger detectors) appears. (The trigger detectors for the preceding event, number 6306, were 0, 1, and 5.)