Last revision 1996 April 18 Bad third STTE board time, Trigger Number 5425 TJD 10188 = 1996 April 15 The auxiliary time words for all of the packets or records for the third board in the STTE data for trigger number 5425, i.e., the words "TIME(1), TIME(2), TIME(3)", seem to be permutated ("permuted" ?) so that the resulting TJD and seconds of day are bad. It is possible that one or maybe two of the words are still not correct even after shifting to compensate for permutation. All of the times are (3) (2) (1) Trig start: 4F98 DF55 2064 = 10188/57173.1296 Trig load: 4F98 DF55 2660 = 10188/57173.1535 STTE Board 1: 4F98 DF52 54ED = 10188/57170.3397 STTE Board 2: 4F98 DF53 BC21 = 10188/57171.7525 STTE Board 3: DF55 2706 4F98 = 12202/75526.3184 STTE Board 4: 4F98 DF57 DBC3 = 10188/57175.8790 It may be that the correct words for "TIME(3),(2),(1)" in hex format for the third STTE board for trigger number 5425 should be 4F98 DF55 2706 = 10188/57173.156 It is, of course, possible that the subseconds number is still wrong and also that the integer seconds number is wrong, although it should be very close.